Font Size: MinusPlus
Print This Page

PRODUCTS & SOLUTIONS

Products

PDT-100


PDT-100

The PDT-100 is equipped with two discrete input and output signals. The input signals can be polled to determine if they have changed state. They can also be used to trigger the transmission of messages (i.e. as an event trigger). Applications include monitoring of door closures, vehicle status, etc.

In addition to its normal mode of operation, with continuous power applied, connected to a data terminal, the PDT-100 can also be operated: a) in a low power mode for supervisory control and data acquisition (SCADA) applications and, b) in a stand-alone mode that provides for autonomous functionality without the need for an external data terminal.


Physical
• Weight: 3lb / 1.4 kg
• Height:5.8 in / 14.732 cm
• Diameter: 7.8 in / 19.812 cm

Input Power
• Voltage (per SAE J1455): 9-16VDC
• Current-Receive Mode: 170mA
• Current-Transmit Mode: 3300mA
• Current- Low Power : 0.5mA

Environmental
• Operating Temperature : -40 to 122 F° / -40 to 50 C°
• Storage Temperature: -55 to 185 F° / - 48 to 85 C°
• Relative Humidity: up to 100%
• Salt spay, fungus, dust, sand, gravel in accordance with SAE J1455
• Railroad Tunnel: 320F° / 160C° for 10 minutes

User Interface
• Electrical: RS232
• Protocol: GSM07.05
• Discrete: 2 inputs, 2 outputs

GPS
• Accuracy: +/- 32.81 ft / 10.000488 m
• Channels: 8 or 12
• Data Format: NMEA 0183